Multi-Layered Laminates |
Graphite-Resin Composites |
|
Boron Fibre Composites |
Kevlar Composites |
|
Glass Fibre Composites |
Composite-to-Substrate |
|
Composite-to-Composite |
Honeycomb Structures |
|
Skin-to-Honeycomb |
Honeycomb-to-Honeycomb |
|
Impact Damage |
Rub Strip |
Examples of a few unique Operational Modes
Impedance Plane with
Air Dot
Sweeping MIA Mode
RF with Bond Profile
in SplitScan
Phase, Amplitude, X & Y
"Live" Reference Curves
Pitch Catch RF Mode
BondaScope 3100 - Ultrasonic Bond Tester -Specifications:
Inputs & Outputs:
0-5VDC - Alarm - Positive or Negative - Latched or Momentary, Phase, Amplitude, X and Y Dot Location - Rate continuous in Resonance and Mechanical Impedance, USB
Power:
Single Li-Ion High Energy Battery Smart Cell. In Battery Microprocessor reports current charge and time to empty - Approx 8 Full Hours Operation
Conditioning Fast Charger provides extended battery life and charge condition calibration. 85-240VAC Auto Sensing
Dimensions:
9.25H x 5.5W x 2.9D - Weight - 5Lbs
Operating Temperature:
-10° to 140°F
Accessories and Options Include:
Full Range of Resonance, Pitch Catch
and MIA probes and Cables, Pellican
Style transport case,
Instrument Soft Pouch,
Spare Batteries, Bond
Profile Encoding Cart,
Data Storage and Transfer
Software - Windows Based.
Contact Us regarding Probe Fixtures and Custom Application Requirements.
Applications include: ALL Laminates, Composites, Honeycomb and more
Probe Samples MIA, Pitch-Catch & Resonance