Corrosion (thickness) mapping is performed through continuous measuring and recording of wall thickness data during XY scanning
-
True-to-location data recording is provided through mechanics free airborne ultrasound determining of probe location on planar and curved surfaces
-
Complete sequence of A-Scans is recorded along with real time back wall surface rendering
-
Off-line evaluation of captured XY wall thickness and A-Scan distribution data is featured with:
-
Sizing of thickness damages at any location of scanned surface: remaining thickness, thickness loss, XY dimensions, and area of damage
-
Play-back and evaluation of A-Scans obtained during scanning
-
Back wall surface profile reconstruction for various Gain and/or Gate settings
-
Statistical analysis of XY wall thickness distribution data and its conversion into MS Excel
®
spreadsheet compatible with various Risk Based Inspection and Maintenance (RBIM) procedures
Typical Application:
Corrosion detection and characterization
|
|
|
Straight beam inspection with 3D data presentation (B-, C-, and D-Scan) is performed through continuous measuring and recording of echo amplitudes and reflectors coordinates during XY scanning:
-
True-to-location data recording is provided through mechanics free airborne ultrasound determining of probe location on planar and curved surfaces
-
Complete sequence of A-Scans is recorded along with real time B-, C-, and D-Scan imaging
-
Off-line evaluation of captured B-, C-, and D-Scan images and A-Scan distribution data is featured with:
-
Sizing of defects at any location of scanned volume: coordinates, XY projection dimensions, and area
-
Play-back and evaluation of A-Scans obtained during scanning; echo-dynamic pattern analysis
-
B-, C-, and D-Scan image reconstruction for various Gain and/or Gate and/or Reject settings
-
Slicing of C-Scan and D-Scan images
-
Statistical analysis of B-, C-, and D-Scan image and its conversion into MS Excel
®
spreadsheet compatible with various Risk Based Inspection and Maintenance (RBIM) procedures
Typical Applications:
Weld and base metal angle beam inspection
For movie illustrating principles of straight beam inspection with 3D data presentation click here
|
|
|
Angle beam inspection with 3D data presentation (P-, D-, and B-Scan) is performed through continuous measuring and recording of echo amplitudes, reflectors coordinates, and probe swiveling angle during XY scanning:
-
True-to-location data recording is provided through mechanics free airborne ultrasound determining of probe location on planar and curved surfaces
-
Complete sequence of A-Scans is recorded along with real time P-, D-, and B-Scan imaging
-
Off-line evaluation of captured P-, D-, and B-Scan images and A-Scan distribution data is featured with:
-
Sizing of defects at any location of scanned volume: coordinates, XY projection dimensions, and area
-
Play-back and evaluation of A-Scans obtained during scanning; echo-dynamic pattern analysis
-
B-, C-, and D-Scan image reconstruction for various Gain and/or Reject settings
-
Slicing of P-Scan and D-Scan images
Typical Application:
Weld and base metal angle beam inspection
For movie illustrating principles of weld inspection and imaging click here
|
|
|