Suppliers of Non-Destructive Test Equipment
Isonic 2005 Thickness Profiles
ADVANCED NDT LIMITED,
Orchard House, Orchard Close, Severn Stoke, Worcester, UK WR8 9JJ
Telephone: 44 (0) 1905 371460 *** Fax: 44 (0) 1905 371477
E-Mail: sales@advanced-ndt.co.uk *** Website: www.advanced-ndt.co.uk
ADVANCED NDT LIMITED,
Orchard House, Orchard Close, Severn Stoke, Worcester, UK WR8 9JJ
Telephone: 44 (0) 1905 371460 *** Fax: 44 (0) 1905 371477
E-Mail: sales@advanced-ndt.co.uk *** Website: www.advanced-ndt.co.uk
Thickness Profile imaging and recording is performed through continuous capturing of Thickness readings along probe trace:
Both time-based (real time clock) and true-to-location (built-in incremental encoder interface mode of data recording are supported
Complete sequence of A-Scans is recorded along with thickness profile
Off-line evaluation of thickness profile record is featured with:
Sizing of thickness damages at any location along stored image: remaining thickness, thickness loss, and length of damage
Play-back and evaluation of A-Scans obtained during scanning
Off-line reconstruction of thickness profile image for various Gain and/or Gate settings
Automatic conversion of thickness profile B-Scan data into MS Excel thickness spreadsheet meeting requirements of various Risk Based Inspection and Maintenance (RBIM)) procedures
Typical Application: Corrosion characterization